表1 工业热源子类温度特征GMM模型
Tab.1 GMM for temperature characteristics of industrial heat source subclasses
企业类别 GMM模型 R2 调整后R2 RMSE/%
冶金 f ( x ) = 4.55 e - x - 874.2 85.41 2 + 3.315 e - x - 1094 1443 2 + 0.2803 e - x - 1531 1302 2 0.993 7 0.993 2 0.114 1
水泥 f ( x ) = 11.52 e - x - 840 93.58 2 0.937 2 0.934 8 0.870 4
石化 f ( x ) = 4.894 e - x - 1191 168 2 + 2.275 e - x - 858.4 119.6 2 + 0.1839 e - x - 1586 206.1 2 0.988 0 0.986 9 0.218 5
煤化 f ( x ) = 4.533 e - x - 1752 103.8 2 + 2.041 e - x - 1776 324.1 2 0.970 9 0.967 6 0.277 8