The authors discuss the principle and conditions of using airborne thermal infrared remote sensing techniques to detect underground oil pipelines. They also analyse the factors, such as the season, time, flying altitude and surface temperature, which affect the results. Data obtained during the first half of the night in the middle of December is judged to be most reliable. 364 subsurface pipelines were located using such data.